Description
Belmont Touch Phot-X IIS Intraoral X-Ray
Reliable with its No Drift Arm
Categories: Intraoral X-Ray, Intraoral X-Rays
Belmont Touch Phot-X IIS Intraoral X-Ray
- Site visit recommended
- Subject to local engineering
- Requires power connection
- Critical Exam required
The Belmont Touch Phot X-IIS is Belmont's hugely popular intraoral X-ray. It has gained such a good reputation due to its clear, reliable imagery and ease of use.
This unit has gained a very strong reputation due to its ease of use, clear imagery and reliable performance, and the sister unit to Belmont's Phot-X Touch.
No Drift Arm
This wall-mounted unit as with all Belmont products is robust and ensures that the sissor arm has no drift, so when you place it in position, it stays there.
Easy to Use
The Phot-X II operates easily. Easily select the right exposure setting and type of patient, as well as the area of the mouth you wish to expose, with clear icons. Manual override functionality. With the control panel mounted outside the surgery.
Versatile
Compatible with all digital systems and film. It can switch between digital and film at the push of a button.
Robust
As with all the Belmont range, the Phot-X II x-ray is built with quality material and made to last and withstand the demands of a a busy practice.
Belmont is a Japanese manufacturer that has established itself in the industry as being one of the best, most reliable brands for a range of equipment including Dental Chairs and X-rays, with a strong UK base in London, with parts and engineers readily available should you require it.
Additional benefits of the Belmont Touch Phot-X II are:
Safety First
A safety-conscious X-Ray unit with exposures as low as 0.01 seconds. Over-exposure is easily avoided with a large range of exposure settings
Ease of Use
It's a user-friendly unit that is simple to operate:
- It has adult, adolescent and child presets for the user or a manual overide for more challenging exposures.
- With a Multilingual display for a range of users.
- A USB for traceability.
- The control panel mounted outside the surgery.
Mounting Options
Choose between wall-mounted, mobile base, unit with stool or ceiling mounted.
Arm Length
Choose between short, medium and long arm mounting.
Focal Spot
Recessed Focal spot allows for the shorter come and longer ‘Source to skin’ distance of 203mm
Easy to Clean
The x-rays screen and the simplicity of the unit make it easy to wipe down.
Specifications for the Belmont Phot-X II Intraoral X-Ray are: | |
X-ray tube | Toshiba D-0711 (Stationary Anode) |
Focal Spot | 0.7 mm |
Target Material | Tungsten |
Target Angle | 16 ̊ |
Maximum anode heat content | 7kJ (10kHU) |
Maximum x-ray tube assembly heat content | 120kJ (170kHU) |
Rated peak tube potential | 60 kV / 70 kV selectable |
Rated tube current | 4 mA / 7 mA selectable |
Maximum rated peak tube potential | 70 kV |
Elitrical Ratings | |
Rated Line Voltage | 230 Vac |
Minimum Line Voltage | 207 Vac |
Maximum Line Voltage | 253 Vac |
Rated Line Power | 1.5 kVA |
Rated Line Current at 70kV,7mA | 6.6 Aac |
Maximum Line Current at 70kV,7mA | 7.3 Aac |
Internal Resistance | 1.02Ω max. |
Range of Line Voltage Regulation | 0 ~ 3 % |
Power line frequency | 50Hz,Single Phase |
Exposure time | 0.01 ~ 3.2 sec. |
Inherent filtration | 1.7 mm Al Equivalent |
Added filtration | 0.3 mm Al |
Minimum filtration permanently in useful beam | 2.0 mm Al Equivalent at 70 kV |
Nominal electrical output of H.V. generator | 0.49 kW at 70 kV, 7 mA |
Regular Cone | Source to skin distance- 203 mm Field Size- mm dia., circular |
Long cone (option) | Source to skin distance- 305 mm Field size- 8 mm dia., circular |
Rectangular cone (option) | Source to skin- 203 mm Field size- 36 x 47 mm, rectangular |
Maximum symmetrical radiation field | 60 mm dia. at distal end of cone |
Leaking technique factor | 70 kV / 0.14 mA (0.14 mA is maximum rated continuous current for 7 mA with a duty cycle 1 : 50) |
Duty cycle | 1 : 50 (0.5 sec. exposure with 25 sec. interval) |
Maximum deviation of tube potential, tube current and exposure time | Below 0.1 sec. setting- ±10 kV, ±2 mA, ±5 msec. 0.1 sec. setting & up- ±5 kV, ±1 mA, ±10 msec. |
Peak tube potential | Average of peak tube potentials during one exposure |
Tube current | Average of tube current during one exposure |
exposure time | Time period during x-ray is emitted |
Half value layer | 1.5 mm Al over |
Source to the base of cone distance | 94 mm |
Environmental condition for storage | -20 ~ 70 ̊C, 10 ~ 90%, 500 ~ 1060hPa |
Environmental condition for operation | 10 ~ 40 ̊C, 30 ~ 75%, 700 ~ 1060hPa |
Movable range of head | Horizontal 0 ~ 600 ̊ Vertical 0 ~300 |
Phot-X IIS Brochure
Practice Design Centre
Visit our extensive showroom, and speak to our refurbishment experts, about creating your ideal working space. Compare equipment (New and Used) and furniture from our world leading brands. Talk interior design and let us help inspire you. Appointments include weekends and evenings.
Equipment Consultation
Talk to the team about a demonstration at your practice for this product. Working alongside the UK dental industry's best manufacturers we will provide honest independent adivce. Equipment trials available on some items.
Hague Dental Team understand the financial demands on any practice. The extensive funds required for any surgery refurbishment, or investment required on the development of a new squat practice. We work alongside leading finance brokers that support the dental industry, to ensure we can quickly and easily help you with finance options. Speak to us about this in more detail.